How can additional CADISON attributes be displayed in the ISOGEN bill of materials?

Solution: (public)

We recommend that you define a separate ISOGEN style for this purpose.

First make a copy of an existing ISOGEN style (e.g. copy the directory "Standard-english" and rename to "Userstyle").

Notes: The location of the ISOGEN style directories is defined in the variable PHI_GLOBALCFG in your CDSN60.INI file. In this example it is in the subdirectory "vcs-igen\STYLE".

Then open the mile matlist.mld in your new style directory in a text editor, and add the desired attributes and their position, each on a new line.

'+<Attribute-Name>' <Start-Coordinate X-Value>

.

For example: To output the object name, starting at X=458, add the line:

'+P_name' 458

.

To activate the new ISOGEN style, enter the new ISOGEN style name in capital letters in the corresponding field on the 807-ISOGEN tab of the project properties.